1. 首页 > 电脑手机 >

管接头标准应用手册_管接头标准最新国家标准

液压管接头是什么材料?

液压管接头材料是什么

管接头标准应用手册_管接头标准最新国家标准管接头标准应用手册_管接头标准最新国家标准


普通液压油对钢管和钢接头没有腐蚀性,所以液压系统中普遍运用碳钢接头,饮用水或纯洁水衔接的管路不应该运用普通碳钢,以前紧缩空气规则运用黄铜管,由于紧缩空气会携带水分,集结在管内,假如用碳钢管会腐蚀管路。先进的空气紧缩机械已不会产生水分,所以这一规则也失去了意义

化工设备管路通常保送各种腐蚀性流体,需求经常运用溶剂或水冲洗。所以,普通化工管路必需是不锈钢。

在思索介质腐蚀性时。主要应思索管路密封件与介质的关系。丁晴橡胶由于与普通的液压油互溶,所以在液压系统应用普遍。丁晴橡胶在一定温度下,还能与合成乙醛,糖基化工液体(HEPG)以及从植物里提出的液体相容,而丁晴橡胶(NBR)不合适在高温下与酸性介质,苯或合成油接触,这时应该运用氟橡胶(FKM),相反,甲烷与制冷氨气却只能与丁晴橡胶(NBR)互溶,所以,大多数化工不锈钢管路都是刚性密封。

选择管接头要晓得管接头的公称压力,公称压力是一个规范参数,并在数值上与系统最大工作压力相等。依照DIN3859-3(ISO19879),最大工作压力要满足4倍静态保险参数以及1.33倍动态保险系数,即爆破检验测出的爆破压力除以4,最大脉冲压力除以1.33,取两值较小值,定义为最大工作压力。

选择管接头时,请求每个接头的最大工作压力最小等于整个液压系统的工作状态的最大设定工作压力,不只要思索泵的出口压力,还要思索溢流阀启动压力。所以,在设计复杂的液压管路时,实践压力最好用现场丈量办法得出。系统工作压力已定,让后要检查每一个选择好的管接头的最大工作压力。

管接头最大工作压力能够因密封方式不同或依据温度变化而变化:同样管接头选择弹性密封就会得到比刚性密封更高的工作压力。

国标规范设定4倍保险系数,缘由是思索了实践设计,管接头装置和设备操作过程可能会呈现的误差,系统工作状态不稳定性等状况,为保证系统在运转时不至于全面瘫痪,所以公称压力的保险系数定的较高。

液压管管接头用什么材质?碳钢还是铸铁?

接头的形式主要有焊接式、扩口式、卡套式等。

铸铁的一般用在低压上。不焊接,靠生料带和螺纹密封。0~1.6mpa吧锭

碳钢的,低碳钢的是焊接接头。中低压都没有问题。1~16mpa没有问题。中高碳钢的没有用过,这个不好焊接。

特殊要求用不锈钢或者铜质的。

美制的有37度锥和74度锥.而且都是细牙的。

DIN液压管接头的产品材料是什么?

碳钢、不锈钢1Cr18Ni9Ti,不锈钢316 山西富朗德提供

液压管接头和接头体以及弯头有什么区别?

液压管接头包括软管接头,钢管接头

接头体是不包括螺母卡套的,有直通接头,弯头,还有是45°接头等等。

弯头一般指的是90°的接头

我这边就是做这块恭,美国PARKER派克进口液压软管,接头,快速接头

评论里有联系方式,谢谢!

液压管接头规格型号主要有哪些

管接头连接形式有螺纹、焊接、卡套等,外形有直通、弯头、三通、变径等。规格型号上万种。你要别人给你说清楚,这个玩笑不好玩。

国内常用的有国标、美标、日标、欧标。你要用哪种?

液压管接头型号有哪些的

国内主要是A、B、C、H型,A型最常见,是平面+O型圈,C型仿日本,球面无圈,H型仿德国,24度锥面+O型圈。

每种都有上百个型号,具体要看手册和样本。

液压油管管接头用做材料的钢材?

如碳钢 和铸铁 后一种用得多 材料费少

不过如果你做的压力大的话弗是见意用碳钢

DIN液压管接头的产品形式是什么

端连接、组合连接、法兰连接、管路连接;可调向接头、旋转接头、单向阀接头等 山西富朗德提供

液压管件是什么?

管件包括管道和管接头,选用原则是:要保证管中油液作层流流动,管路尽量短以减小压力损失;根据工作压力,安装位置来确定管材和连接结构,以保证管道和管接头有足够的强度,良好的密封性;与泵,阀等连接的管件应由其接口尺寸决定管径;装拆方便。 山西富朗德液压技术有限公司提供

液压管接头的管路正式安装

清洗后的管路应尽快正式安装并充脂(1) 将所有管路按打印的配合记号逐段连接;(2) 按第4章方法紧固全部管接头,注意要放入原先拆下的o型圈;(3) 所有配管的固定应牢固,不能松动;(4) 所有给油管可留待充脂后再同分配器出油口及润滑点连接。液压管接头—螺纹标准二一. 螺纹的分类1. 螺纹分内螺纹和外螺纹两种;2. 按牙形分可分为:1)三角形螺纹 2)梯形螺纹 3)矩形螺纹 4)锯齿形螺纹;3. 按线数分单头螺纹和多头螺纹;4. 按旋入方向分左旋螺纹和右旋螺纹两种, 右旋不标注,左旋加LH,如M24×1.5LH;5. 按用途不同分有:米制普通螺纹、用螺纹密封的管螺纹、非螺纹密封的管螺纹、60°圆锥管螺纹、米制锥螺纹等二. 米制普通螺纹1. 米制普通螺纹用大写M表示,牙型角2α=60°(α表示牙型半角);2. 米制普通螺纹按螺距分粗牙普通螺纹和细牙普通螺纹两种;2.1. 粗牙普通螺纹标记一般不标明螺距,如M20表示粗牙螺纹;细牙螺纹标记必须标明螺距,如M30×1.5表示细牙螺纹、其中螺距为1.5。2.2. 普通螺纹用于机械零件之间的连接和紧固,一般螺纹连接多用粗牙螺纹,细牙螺纹比同一公称直径的粗牙螺纹强度略高,自锁性能较好。3. 米制普通螺纹的标记:M20-6H、M20×1.5LH-6g-40,其中M 表示米制普通螺纹,20表示螺纹的公称直径为20mm,1.5表示螺距,LH表示左旋,6H、6g表示螺纹精度等级,大写精度等级代号表示内螺纹,小写精度等级代号表示外螺纹,40表示旋合长度;3.1. 常用米制普通粗牙螺纹的螺距如下表(螺纹底孔直径:碳钢φ=公称直径-P;铸铁φ=公称直径-1.05~1.1P;加工外螺纹光杆直径取φ=公称直径-0.13P):表1 常用米制普通粗牙螺纹的直径/螺距公称直径 螺距P 铸铁底孔 碳钢底孔 外螺纹光杆直径 公称直径 螺距P 铸铁底孔 碳钢底孔 外螺纹光杆直径M5 0.8 4.1 4.2 4.9 M24 3 20.8 21 23.7M6 1 4.9 5 5.9 M27 3 23.8 24 26.7M8 1.25 6.6 6.7 7.9 M30 3.5 26.3 26.5 29.6M10 1.5 8.3 8.5 9.8 M33 3.5 29.3 29.5 32.6M12 1.75 10.3 10.4 11.8 M36 4 31.7 32 35.5M14 2 11.7 12 13.7 M42 4.5 37.2 37.5 41.5M16 2 13.8 14 15.7 M48 5 42.5 43 47.5M18 2.5 15.3 15.5 17.7 M56 5.5 50 50.5 55.5M20 2.5 17.3 17.5 19.7 M64 6 57.5 58 63.53.2. 米制普通内螺纹的加工底孔直径可用下式作近似计算:d=D-1.0825P,其中D为公称直径,P为螺距。三. 用螺纹密封的管螺纹(GB 7306与ISO7/1相同)1. 用螺纹密封的管螺纹不加填料或密封质就能防止渗漏。用螺纹密封的管螺纹有圆柱内螺纹和圆锥外螺纹、圆锥内螺纹和圆锥外螺纹两种连接形式。压力在5×105Pa以下时,用前一种连接已足够紧密,后一种连接通常只在高温及高压下采用。2. 用螺纹密封的管螺纹内螺纹有圆锥、圆柱两种形式。外螺纹只有圆锥一种形式。牙型如下:锥度1:16,牙形角55°,旧螺纹标准示例:ZG3/8;3. 标记示例:圆锥内螺纹 Rc 3/8圆柱内螺纹 Rp3/8圆锥外螺纹 R3/8当螺纹为左......

MVCR是一种接头类型,常用于压力表的连接。MVCR全称为“mechanical vacuum compression ring”,即机械性真空压缩环接头。采用MVCR接头的压力表可以在高压和高温条件下工作,具有更好的密封性和耐用性。

MVCR接头具有凸缘连接和压缩环连接两种形式。凸缘连接的MVCR接头通常用于连接仪器和管道之间的高压装置,而压缩环连接的MVCR接头则通常用于连接压力表和管道之间的低压装置。

MVCR接头的优点包括连接紧密、密封可靠、适用于大部分管径和形状的管道等。在使用MVCR接头时,需要特别注意保持接头清洁和正确安装,以确保其正常工作、不泄漏以及长期使用寿命。

MVCR接头是一种常见的压力表接头,它是由一根金属管和两个端口组成的。其中一个端口连接到压力表上,另一个端口连接到被测试的压力系统上。MVCR接头的管壁上有一个小孔,可以通过这个孔将被测压力传递到压力表上。

MVCR接头的优点是它可以确保压力传递的准确性和稳定性,同时还具有较高的密封性和耐用性。此外,它还可以承受高压和高温条件下的应用,因此在许多工业和实验室应用中得到广泛使用。

需要注意的是,MVCR接头的安装和使用需要严格按照厂家的说明进行,以确保安全和准确性。在使用过程中,还需要注意定期检查和维护接头,以确保其正常工作和长期使用。

压力表MVCR是一种可调节压力的压力表接头,主要用于连接压力表与被测压力系统,可用于测量液体或气体的压力。该接头采用常用的1/4英寸和3/8英寸接头,适用于不同尺寸的压力表。MVCR接头采用可调节的旋转螺母设计,可通过旋转调节压力表的读数,具有较高的精度和稳定性。该接头的材质通常为不锈钢或黄铜,具有较好的耐腐蚀性和强度,可适用于多种环境和应用领域。在使用过程中,需要注意接头的安装和调节,以确保测量结果的准确性和可靠性。

压力表MVCR是法兰夹连接的接头类型,适用于压力表和压力变送器的实际使用环境中。与传统的螺纹接头相比,法兰夹接头不易产生泄漏,并具有更强的抗震性和耐腐蚀性。在使用压力表和压力变送器时,正确连接接头是保证设备正常工作的关键之一,因此建议用户在选择接头类型时应根据实际工作环境和需要进行综合考虑,选择适当的接头类型。

MVCR是一种压力表的接头类型,通常用于连接高压管道和仪器设备,以测量管道内的压力。MVCR接头的特点是具有可靠的密封性能,能够承受高压并且不易泄漏。该接头采用金属密封技术,使用时需要注意安装和拆卸的方式,以免损坏密封件。MVCR接头通常由三部分组成,包括接头本体、密封环和夹紧圈。接头本体是连接管道和仪器设备的主要部分,密封环则是确保密封性能的关键部件,夹紧圈则用于固定密封环和接头本体。总之,MVCR接头是一种高压、高可靠性的压力表接头,广泛应用于石油、化工、航空航天等领域。

MVCR 接头是一种螺纹连接的压力表接头。MVCR 代表的是 Metal Gasket Face Seal (金属垫面密封) Connector Reduced (减过流)。该接头通常使用于高精度压力测量设备和仪器中,能够提供高度的密封性和可靠性。

MVCR 接头通常是由三个主要部分组成:一种内部凸台、一种中间垫片和一种外部圆盘。这些部件共同提供一个完全密封的连接,能够防止任何情况下的泄露或渗漏。MVCR 接头还通常被制成耐腐蚀材料,以便在各种极端环境中使用,这些环境可能会损伤传统 O 型密封环。MVCR 接头的紧固方式为螺纹,并且可靠性非常高,能够承受高压和高温。

总而言之,MVCR 接头是一种高度精确、可靠性强且适用于各种严苛的应用的压力表接头。

答案:MVCR是一种压力表接头,它是由M(男)和V(女)两个接头组成的,CR是压力表的连接标准型号。MVCR接头通常用于连接压力表和压力袋或管道。

解释:MVCR接头是一种常用的压力表连接方式,它可以方便地连接压力表与袋式过滤器、管道等设备,使压力表可以测量液体或气体的压力。MVCR接头通常由不锈钢或铜制成,具有耐腐蚀、高温、抗压等特点,适用于各种工业场合。

拓展:除了MVCR接头,还有其他类型的压力表接头,如NPT接头、BSP接头、插销式接头等。不同类型的接头适用于不同的压力表和管道连接方式,使用时需要根据实际情况进行选择。此外,正确的接头安装和连接也是保证压力表测量准确的重要因素,需要注意细节和操作规范。

无缝弯头标准无缝弯头的特点

近年来随着我国电力建设的加速发展和新技术新材料的不断推广,无缝弯头已应用到国内几十家新建电厂工程上,使用效果良好,得到大力推广。下面小编为大家介绍无缝弯头标准的相关知识。

无缝弯头的特点:

无缝弯头有以下优点:卫生无毒,重量轻,耐热性好,耐腐蚀性好,保温性好,抗冲性能好,使用寿命长的特点

1、卫生无毒:材料完全由碳、氢两种无素组成,未添加任何有毒的重金属盐稳定剂,材料的卫生性能已经通过国家权威部门检测。

2、重量轻:冲压弯头密度为0.89-0.91g/cm,仅为钢管的十分之一。由于重量轻,可大大工业降低运输费用和安装的施工强度。

3、耐热性能好:当工作水温为70度,软化的温度为140度。

4、耐腐蚀性好:除少数氢化剂外,可耐多种化学介质的侵蚀,具有优异的耐酸、耐碱、耐腐蚀性、不会生锈,不会腐蚀,不会滋生细菌,无电化学腐蚀。

5、保温性好:由于材料导热系数低,20摄氏度的导热系数为0.21-0.24W/mk,比钢管(43-52W/mk)、紫钢管(333W/mk)小得多,故PP-R管保温性好。

6、高抗冲:由于独特的抗冲强度性能比其它实壁管有了明显改善,其环刚度相当于实壁的1.3倍。

7、使用寿命长:管材在额定的使用温度和压力下,使用寿命达到50年以上,具有防紫外线、防辐射,使产品永不褪色。

无缝弯头标准:

日本标准

标准号描述JISB2311通用钢制对焊管件

JISB2312钢制对焊管件

JISB2313钢板制对焊管件

JISB2316钢制承插焊管件

管件执行标准之美国标准:

标准号描述

ASME/ANSIB16.9工厂制造的锻钢对焊管件

ASME/ANSIB16.11承插焊和螺纹锻造管件

ASME/ANSIB16.28钢制对焊小半径弯头和回头弯

ASMEB16.5管法兰和法兰配件

MSSSP-43锻制不锈钢对焊管件

MSSSP-79承插焊异径插入件

MSSSP-83承插焊和螺纹活接头

MSSSP-97承插焊、螺纹和对焊端的整体加强式管座

电力标准

标准号描述

GB2000火电发电厂汽水管道零件及部件典型设计手册

DL/T515-93电站弯管

D-GD87-1101管道零件及部件典型设计

管件执行标准之化工标准:

标准号描述

HGJ514碳钢、低合金钢无缝对焊管件

HGJ528钢制有缝对焊管件

HGJ10锻钢制承插焊管件

HGJ529锻钢制承插焊、螺纹和对焊接管台

HGJ-44-76-91钢制管法兰、垫片、紧固件

HG20592-20635钢制管法兰、垫片、紧固件

中石化标准

标准号描述

SH3406-1996石油化工钢制管法兰

SH3408-1996钢制对焊无缝管件

SH3409-1996锻钢制承插焊管件

SH3410-1996锻钢制承插焊管件

SH3065-1994石油化工管式炉急弯弯管技术标准

国家标准

标准号描述

GB/T12459-2005钢制对焊无缝管件

GB/T13401-2005钢板制对焊管件

GB/T14383锻钢制承插焊管件

GB/T17185-1995钢制法兰管件

管件执行标准之中石油标准:

标准号描述

SY/T0510-1998钢制对焊管件

SY/T5257-2004钢制弯管

02S403钢制管件国家建筑标准

船用标准

GB/T10752-1995船用钢管对焊接头

CB/T3590-94铝黄铜弯头

铸铁管国标规格表如下图:

铸铁管按铸造方法不同,可以分为连续铸铁管和离心铸铁管,其中离心铸铁管又可以分为砂型和金属型两种。按材质不同可以分为灰口铸铁管和球墨铸铁管。

按接口形式不同分为柔性接口、法兰接口、自锚式接口、刚性接口等。其中,柔性铸铁管用橡胶圈密封;法兰接口铸铁管用法兰固定,内垫橡胶法兰垫片密封;刚性接口一般铸铁管承口较大,直管插入后,用水泥密封,此工艺现已基本淘汰。

铸铁管的选用建议:

1、对于球墨铸铁管材的选择应根据敷设地具体情况,选择直管与配件的接口形式。

2、橡胶圈最好选用NBR、SBR、EPDM等材质。

3、涂层的选择:依据使用时的内、外部条件选择适和的涂层。现有内涂层为环氧树脂、聚氨酯内外涂层、PE 膜涂层等球墨铸铁管新产品,选用时应详细了解其性能。

以上内容参考:

这两本电子书对你肯定有用

二次系统安全防护设备—防火墙设备

采购标准技术规范使用说明

1. 本标准技术规范分为通用部分和专用部分。

2. 项目单位根据需求选择所需设备的技术规范。技术规范通用部分条款、专用部分标准技术参数表和使用条件表固化的参数原则上不能更改。

3. 项目单位应按实际要求填写“项目需求部分”。如确实需要改动以下部分,项目单位应填写专用部分“项目单位技术差异表”,并加盖该网、省公司物资部(招投标管理中心)公章,与辅助说明文件随招标计划一起提交至招标文件审查会:

1) 改动通用部分条款及专用部分固化的参数;

2) 项目单位要求值超出标准技术参数值范围;

3) 根据实际使用条件,需要变更环境温度、湿度、海拔、耐受地震能力、用途和安装方式等要求。

经招标文件审查会同意后,对专用部分的修改形成“项目单位技术差异表”,放入专用部分表格中,随招标文件同时发出并视为有效,否则将视为无差异。

4. 投标人逐项响应技术规范专用部分中“1标准技术参数表”、“2项目需求部分”和“3投标人响应部分”三部分相应内容。填写投标人响应部分,应严格按招标文件技术规范专用部分的“招标人要求值”一栏填写相应的投标人响应部分的表格。投标人还应对项目需求部分的“项目单位技术差异表”中给出的参数进行响应。“项目单位技术差异表”与“标准技术参数表”和“使用条件表”中参数不同时,以差异表给出的参数为准。投标人填写技术参数和性能要求响应表时,如有偏差除填写“投标人技术偏差表”外,必要时应提供证明参数优于招标人要求的相关试验报告。

5. 对扩建工程,如有需要,项目单位应在专用部分提出与原工程相适应的一次、二次及土建的接口要求。

6. 技术规范范本的页面、标题等均为统一格式,不得随意更改。

7. 一次设备的型式、电气主接线和一次系统情况对二次设备的配置和功能要求影响较大,应在专用部分中详细说明。

目 次

二次系统安全防护设备—防火墙设备采购标准技术规范使用说明 ························································· 217 1 总则 ······················································································································································· 219

1.1 引言 ·················································································································································· 219

1.2 投标人职责 ········································································································································ 219 2 技术规范要求 ······································································································································· 220

2.1 环境要求 ··········································································································································· 220

2.2 电源要求 ··········································································································································· 220

2.3 防火墙设备基本要求 ··························································································································· 220

2.4 防火墙设备功能要求 ··························································································································· 221

2.5 日志报表要求 ····································································································································· 222

2.6 管理要求 ··········································································································································· 222

2.7 自身安全性要求 ·································································································································· 222 3 试验和验收 ··········································································································································· 222

3.1 安装调试 ··········································································································································· 222

3.2 设备验收 ··········································································································································· 223 4 技术服务 ··············································································································································· 223

4.1 技术服务 ··········································································································································· 223

4.2 培训 ·················································································································································· 224

1 总则

1.1 引言

本技术规范书为防火墙设备招标的主要技术功能要求、供货要求、服务要求,供投标人编制项目建议书及报价之用。

1.1.1 投标人及投标产品应具备如下资质:

1) 投标人需具有ISO9001质量保证体系认证证书、宜有ISO14001环境管理体系认证

证书、宜有OHSAS18001职业健康安全管理体系认证证书,并具有AAA 级资信等级证书、宜有重合同守信用企业证书并具备良好的财务状况和商业信誉。

2) 投标产品必须为自主知识产权的国产设备,经公安部、国家信息安全测评认证中心

等国家权威部门测试通过,并获得安全产品销售许可证,评测认证资质必须在两年内有效。

3) 若投标人为系统集成商,需提供原厂商的代理资质证明;同时保证有直接向原厂商

下单权限并直接获得原厂商售后技术服务支持的权限。

4) 投标产品应在电力行业测评机构经过测评,必须符合变电站电磁兼容要求的电磁兼

容三级要求,符合变电站环境中应用要求,出具相应检测报告。

5) 投标人应提供三年以内在电力行业网、省级公司及以上网络的应答产品的应

用案例3个以上。

1.1.2 投标人应具有设计并集成过规模与本工程类似或更大的、条件与本工程规定相当或更严格的网络安全系统的业绩,并提供业绩清单,用户证明,联系人地址、电话。

1.1.3 本次投标的所采用的设备及主要安全防护技术,至少要有与本工程同等规模的系统中有1年以上成功商业运行经验。所投标的设备应经过有资质的检测机构的检测,并提供检测报告、业绩清单,用户证明,联系人地址、电话;如发现有失实情况,招标人有权拒绝该投标。

1.1.4 投标人在建议书中,对本技术规范书中所提的技术及工程要求,应逐项予以说明和答复。对涉及到的主要产品、技术及服务,应做出详细说明。投标人亦可根据产品技术性能的具体情况,在建议书中提出建议,并附详细资料和说明。对本规范书各条目的应答为“满足”、“不满足”、“部分满足”,不得使用“明白”、“理解”等词语,如出现上述应答,将视为不符合要求且该应答无效,在答复中,要求明确满足的程度,并做出具体、详细的说明,凡采用“详见”、“参见”方式说明的,应指明参见文档中的具体的章节或页码,凡要求进行说明而未做说明的,视该条应答无效。

1.1.5 本技术规范书应视为保证网络运行所需的最低要求,如有遗漏,投标人应予以补充,否则一旦中标将认为投标人认同遗漏部分并免费提供。

1.1.6 招标人保留对本文件的解释和修改权。

1.2 投标人职责

投标人的工作范围将包括下列内容,但不仅仅限于此内容。

1.2.1 投标人提供的产品必须满足本规范书所描述的硬件设备及外设配置要求,这是招标人提出的设备最低配置要求。

1.2.2 投标人所提供的所有设备需完全满足本采购所述规格,所有需要的硬件需配齐以构成一套完整实用产品。如果投标人所列出的硬件设备及外部设备的配置建议,当实际采购时其软、硬件有任何遗漏(包括技术规范书中未列出而设备正常运行又需要的软硬件),则设备正常运行需要时投标人必须免费提供,招标人将不再支付任何费用。

1.2.3 招标人非常重视投标人在应答方案中所推荐产品的生命周期,要求所推荐的产品在未来两年内不能停产或淘汰。

1.2.4 在招标人购买整机之日起,投标人对其所有部件保证五年供应。

1.2.5 所有硬件系统均需符合下述标准:

电磁学规范:FCC Class B或CISPR 22 Class B;

安全规范:UL Listed(美国)或EN 60950(国际);

质量标准:ISO9000认证。

1.2.6 投标人必需提供下列技术资料:

各种设备机架(柜)外型尺寸、重量、面板布置、进出线方式;

所需电源种类、功耗、电压、地线要求;

机房荷重、环境要求;

设备安装方式和抗震措施;

设备、线缆、端口等的实施维护标识办法。

1.2.7 投标人应提供由中国信息安全测评中心或电力行业内专业测评机构出具的覆盖全部技术指标项的测评报告。

1.2.8 如果应答设备要求使用特别接头、插座等,由投标人提供。另外,所投设备的用电保护超过一般线路保护,保护设备也由投标人提供。

1.2.9 设备/产品基于国际标准或工业标准,成熟、互联性强、易扩充。

1.2.10 软件系统及相关硬件有最佳的匹配和应用运行能力。

1.2.11 投标人必须提供产品相应的、配套的、正式的中文或英文版技术参考手册、安装及管理维护手册和使用手册。

1.2.12 所有软件系统如果有使用时限问题,必须在应答书中明确说明。所有软件产品必须提供符合项目目标环境的安装介质,必须提供相应配套的、正规出版的中文版技术参考手册、安装及维护管理手册和招标人使用手册。

1.2.13 投标人提供的所有硬件设备必须是全新的、出厂的新设备,软件产品应是最新版的商用版本,提供的产品准许在中华人民共和国境内销售、能够在中国境内和合法使用,且在性能及质量方面能提供可靠证明,并享有设备制造商承诺的质量保证。同时,应对此软、硬件所涉及的专利、知识产权等法律条款承担义务,招标人对此不承担任何责任。

1.2.14 投标人需提供应答设备及推荐设备的产品销售许可证书。

1.2.15 提供实施计划 ,制造和质量保证过程的一览表以及标书规定的其他资料。

1.2.16 提供设备管理和运行所需有关资料。

1.2.17 现场服务。

2 技术规范要求

2.1 环境要求

2.1.1 设备储存温度: 40℃~+55℃;

2.1.2 设备工作温度:0~+45℃;

2.1.3 大气压力:86~106kPa ;

2.1.4 相对湿度:30%~85%;

2.1.5 抗地震能力:地面水平加速度0.3g ,垂直加速度0.15g 同时作用。

2.2 电源要求

设备采用交流电源供电,并在下列供电变化范围内正常工作:

交流:220V ±10%,50Hz ±5%。

投标人应详细说明所供设备本期配置功耗及满配功耗。

2.3 防火墙设备基本要求

装置至少应满足表1中最新版本的规定、规范和标准的要求,但不限于表1中规范和标

准。

表1 投标人提供的设备和附件需要满足的主要标准

2.4 防火墙设备功能要求

2.4.1 防火墙设备应具有包过滤功能,包括但不止于以下功能:

2.4.1.1 支持基于IP 地址的访问控制。

2.4.1.2 支持基于协议、端口的访问控制。

2.4.1.3 支持基于MAC 地址的访问控制。

2.4.1.4 支持基于时间的访问控制。

2.4.1.5 支持基于IP 地址、协议、端口、时间等参数组合的访问控制。

2.4.2 防火墙设备应具有深度包检测功能,包括但不止于以下功能:

2.4.2.1 支持基于URL 的访问控制。

2.4.2.2 支持SMTP ,POP3协议,可对电子邮件中Subject 、To 、From 域等进行访问控制。

2.4.2.3 支持基于HTTP ,FTP ,SMTP ,POP3协议的文件类型的访问控制。

2.4.2.4 支持基于HTTP 页面及电子邮件正文的关键字访问控制。

2.4.3 防火墙设备应支持SNA T 、DNA T 的动态网络地址转换。

2.4.4 防火墙设备应支持IP/MAC地址绑定。

2.4.5 防火墙设备应具有动态开放端口功能,包括但不止于以下功能:

2.4.5.1 支持FTP 的动态端口开放。

2.4.5.2 支持以H.323协议建立视频会议。

2.4.5.3 支持SQL.NET 数据库协议。

2.4.6 防火墙设备应具有网络适应及路由策略功能,包括但不止于以下功能:

2.4.6.1 支持静态路由、动态路由(RIP 、OSPF )。

2.4.6.2 支持路由、透明和混合工作模式。

2.4.6.3 支持VLAN TRUNK网络环境(802.1q )。

2.4.6.4 支持根据数据包信息设置策略路由。

2.4.7 应能够基于IP 地址、协议、时间等参数对流量进行统计,可根据不同条件设置统计规则

2.4.8 应支持基于IP 地址及协议的带宽管理功能。

2.4.9 应支持物理设备状态及链路状态检测的双机热备,支持状态同步,切换时间小于或等于5s 。

2.4.10 应支持网络负载均衡到多台服务器。

2.4.11 设备需要支持网络时间同步协议NTP ,支持NTP 认证和NTP 客户端。

2.5 日志报表要求

2.5.1 防火墙设备应具有日志记录功能,包括但不止于以下功能:

2.5.1.1 支持记录被安全策略允许、拒绝的访问请求。

2.5.1.2 支持记录防火墙的管理行为、认证请求。

2.5.1.3 审计记录的内容应至少包括时间、日期、事件类型、事件描述、处理结果等。

2.5.2 应支持日志的统计分析和报表生成,能够基于IP 地址、协议等条件定制生成报表。

2.5.3 装置应具有集中管理功能,可对分布式的防火墙进行统一集中管理;支持日志集中管理。

2.5.4 应支持日志的授权访问,授权用户可对日志进行检索、清空、备份等操作。

2.5.5 应支持日志存储耗尽处理机制,如向管理员报警、覆盖最早的日志等。

2.6 管理要求

2.6.1 支持管理员权限划分。

2.6.2 支持对授权管理员的口令、Radius 等认证鉴别方式,提供鉴别失败处理机制,支持对管理IP 地址进行设置。

2.6.3 防火墙设备应具有多种管理方式,包括但不止于以下功能:

2.6.3.1 支持本地和远程安全管理。

2.6.3.2 支持软件升级。

2.6.3.3 具有中文GUI 界面,通过GUI 能够完成全部配置、管理工作,支持中文对象名。

2.6.4 支持配置的备份与恢复,允许恢复出厂设置。

2.6.5 支持防火墙状态监控,如CPU 、内存、端口状态;支持网络流量状态监控。

2.7 自身安全性要求

2.7.1 应能抵抗各种典型的拒绝服务攻击,如SYN Flood,UDP Flood,ICMP Flood。

2.7.2 能抵抗IP 碎片包攻击。

2.7.3 能抵御源IP 地址欺骗攻击。

2.7.4 能够检测和记录端口扫描行为,不返回敏感信息。

3 试验和验收

3.1 安装调试

安装地点和环境在买方指定的地点,卖方或制造商应负责设备的安装、调试,保障设备正常运行。卖方需明确以下问题:

3.1.1 设备安装由卖方负责,安装过程中所有电缆及接头均由卖方提供并施工。

3.1.2 卖方负责对施工地点进行现场勘察,提供工程施工和相关安装资料,并负责指导买方人员掌握和使用这些技术资料。卖方应提供下列各种详细资料:

3.1.2.1 设备外型尺寸、重量、面板布置、进出线方式。

3.1.2.2 所需电源种类、功耗、电压、地线要求。

3.1.2.2 机房荷重、环境要求。

3.1.2.3 设备安装方式和抗震措施。

3.1.3 安装调测时使用的工具、设备由卖方提供,通用工具由买方协助解决。双方应协商制定工程进度表,卖方负责按工程进度表进行施工。

3.1.4 设备调试由卖方负责,卖方调试前应提出完整的调试计划并经买方确认,包括设备调试的内容、项目、指标、方法和进度,并提供相应的仪器和工具。卖方有责任对买方的技术人员提出的问题做出解答。调试应进行详细记录,系统调试结束后,由卖方技术人员签字后交给买方验收。

3.2 设备验收

3.2.1 项目单位与卖方或制造商对设备到货后共同配合进行开箱检查,出现损坏、数量不全或产品不对等问题时,由卖方或制造商负责解决。

3.2.2 依技术规范书要求对全部设备、产品、型号、规格、数量、外型、外观、包装及资料、文件(包括装箱单、保修单、随箱介质等)的验收。

3.2.3 根据技术规范书要求,全部设备在技术规范书规定的地点和环境下, 进行安装、调试,加电实现正常运行,并达到技术规范书要求的性能和产品技术规格中的性能。

3.2.4 按规范书技术部分要求对产品进行测试检查。设备产品测试中出现性能指标或功能上不符合规范书和合同时,项目单位有拒收的权利。

3.2.5 如验收及测试中出现不符合规范书和合同要求的严重质量问题时,买方保留索赔权利。

3.2.6 技术文档齐全,包括操作手册、配置参数手册、排错手册、管理维护手册等其他技术文件,如果有中文设备技术文件,必须提供中文版本的设备技术文件,如没有,必须提供英文版设备技术文件。

4 技术服务

4.1 技术服务

4.1.1 技术后援支持

卖方或制造商必须向买方承诺技术后援支持,为今后买方主要软、硬件设备的功能扩充、服务提供至少五年的技术支持。

4.1.2 质保及售后服务

4.1.2.1 质保及售后服务

本技术规范书中所有设备必须有以下条件:

质保:所有本规范书内包含的产品质保期为36个月,对于设备,包括硬件、软件,在质保期内,提供免费的生产原厂商软件升级包和免费的生产原厂商设备保修备件;质保期自设备通过最终验收之日起计算,其费用计入总价。请卖方或制造商详细描述质保方案。

售后服务:卖方或制造商需提供质保期内免费的7×24h 技术支持与服务。卖方或制造商必须按照如下格式对服务响应时间进行明确描述。“设备出现故障时必须在2h 内对买方所提出的维修要求做出响应,12h 内到达现场。对于24h 解决不了的问题,应提供备用设备。”卖方或制造商如有其他服务响应可以另加描述。

卖方或制造商详细说明所提供的设备原厂商三年售后服务与技术支持的级别及服务内容。应答人必须提出质保期内的维修、维护内容及服务方式、范围(产品、技术、模块、部件)。

在质保期内,应答人应提供相关软件的免费升级和备品更换服务;应答应人负责对其提供的设备进行现场维修与维护,不收取额外费用;在质保期后应答人应以不高于本合同相应的最优惠价格向买方提供修理和维修合同设备必要的备品备件。

要求各应答人承诺在产品交付时提供针对交付产品的原厂三年质保函。

4.1.2.2 质保期后的质保与售后服务

卖方或制造商按照上述质保与售后服务为标准为买方提供质保期后的维保方案和报价,不计入总价。

在质保期过后,卖方或制造商应以不高于本合同相应的最优惠价格向买方提供修理和维修合同设备必要的备品备件。

原厂商技术支持站点(或办事处)与原厂商备品备件库。

卖方或制造商需提供国家电网公司涉及地理区域范围内的原厂商技术支持站点及原厂商备品备件库。

4.2 培训

4.2.1 培训总则

1) 培训服务为项目单位自愿采购内容。

2) 卖方提供的培训服务必须满足4.2章要求。

3) 卖方必须提供高水平的培训。培训应包括硬件、软件等。所提供的培训课程表随应

答文件一起提交。

4) 卖方派出的培训教员应至少具有三年的相同课程的教学经验。

5) 所有的培训教员必须用中文授课(如果讲师不会讲中文,卖方必须提供中文翻译),

除非有其他的协议规定。

6) 卖方必须为所有被培训人员提供培训用计算机、网络环境、文字资料和讲义等相关

用品。所有的资料必须是中文。

7)培训场所由卖方提供。

8)培训时间和日期与招标方协商决定。

9)培训费用根据培训内容按照每人每天计算。

10) 培训费用单独报价,不计入总价。

11) 卖方应提供现场免费培训。

4.2.2 培训内容与课程要求

1) 培训内容应包括:卖方所提供的软、硬件设备的相关技术原理、性能、操作使用方

法、维护管理的技术、实际的操作练习等。使买方具备独立进行管理、维护测试和故障处理等工作的能力,以保证卖方所提供的设备能够正常、安全运行。

2) 培训费用包括课程费、资料费等,不计入总价。

3) 提供详细培训体系内容。

版权声明:本文内容由互联网用户自发贡献,该文观点仅代表作者本人。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌抄袭侵权/违法违规的内容, 请发送邮件至836084111@qq.com 举报,一经查实,本站将立刻删除。